Product basic info: "
†Instruction manual languages: Dutch, English, French, German, Polish, Portuguese, Spanish "
†Primary colours: Black "
†Additional colours: Red "
†Depth unit: 40 mm "
†Height unit: 190 mm "
†Width unit: 100 mm "
†Weight unit: 300 g "
†Material: ABS "†Physical properties: "
†Cable length: 0.75 m "
†Display height: 36 mm "
†Display width: 62 mm "
†Display type: LCD "
†Backlight: Yes "
†Maximum digits display: 1999 "†Electrical data: "
†AC current:
†AC voltage:
†Audible continuity measurement: Yes "
†Audible continuity:
†Automatic polarity indication: Yes "
†Capacity:
†DC current:
†DC voltage:
†Diode test: Yes "
†Diode test specifications: test voltage: approx. 3 V (reversed DC voltage)
"
†Frequency:
†Fuse type: F 0.50 A / 600 VAC / 500 VDC, 5 x 20 mm, breaking capacity 1 kA, F 15 A / 1000 VAC / 1000 VDC, 6 x 32 mm, breaking capacity 10 kA "
†Out of range indication: Yes "
†Temperature measuring Celsius specifications:
†Transistor test: No "
†AC current measurements: 15 A, 2 mA, 20 mA, 200 µA, 200 mA "
†AC voltage measurements: 0-2 V, 20 V, 200 V, 600 V "
†Capacity measurements: 2 µF, 20 nF, 200 µF, 200 nF, 2000 pF "
†DC current measurements: 0.2 mA, 15 A, 2 mA, 20 mA, 200 µA, 200 mA "
†DC voltage measurements: 0-200 mV, 2 V, 20 V, 200 V, 600 V "
†Frequency measurements: 20 kHz "
†Resistance measurements: 0-200 Ohm, 2 kOhm, 2 MOhm, 20 kOhm, 20 MOhm, 200 kOhm, 200 MOhm "
†Resistance specifications:
†Safety rating: Cat III / 600 V, Cat IV / 300 V "
†Voltage tester type: AC / DC "
†Automatic power-off function: Yes "
†Pollution degree: 2 "
†Data-hold function: No "†Environmental data: "
†IP rating: IPx0 "
†Usage location: Indoor only "
†Operating temperature °C: 0-40 °C "
†Operating temperature °F: 32-104 °F "
†Storage temperature °C: -20-60 °C "
†Storage temperature °F: -4-140 °F "
†Maximum storage humidity: 90 % "
†Maximum operating humidity: 80 % "†Operational properties: "
†M
†Instruction manual languages: Dutch, English, French, German, Polish, Portuguese, Spanish "
†Primary colours: Black "
†Additional colours: Red "
†Depth unit: 40 mm "
†Height unit: 190 mm "
†Width unit: 100 mm "
†Weight unit: 300 g "
†Material: ABS "†Physical properties: "
†Cable length: 0.75 m "
†Display height: 36 mm "
†Display width: 62 mm "
†Display type: LCD "
†Backlight: Yes "
†Maximum digits display: 1999 "†Electrical data: "
†AC current:
- basic accuracy: ± (1.5% rdg + 3 digits), ± (2.0% rdg + 3 digits) for 200mA range, ± (2.5% rdg + 5 digits) for 15 A range
- overload protection: 500 mA / 600 V, 15 A / 600 V fuse
- frequency range: 40-500 Hz
†AC voltage:
- basic accuracy: ± (0.8% rdg + 3 digits) , ± (1.2% rdg + 3 digits) for 600 V range
- input impedance: 1 megohm for 2 V range, 10 megohm for other ranges
- frequency range: 40-500 Hz
- maximum input: 600V DC or AC rms
- test A: <= or <,=
- test B: >= or >,=
†Audible continuity measurement: Yes "
†Audible continuity:
- built-in buzzer sounds if resistance is less than 50 Ohm
- test voltage: approx. 3 V
†Automatic polarity indication: Yes "
†Capacity:
- basic accuracy: ± (2.5% rdg + 10 digits) for 2000 pF range, ± (2.5% rdg + 5 digits) for 20nF to 20 µF range, ± (5.0% rdg + 10 digits) for 200 µF range
- overload protection: 500 mA / 600 V fuse
†DC current:
- basic accuracy: ± (1.2% rdg + 2 digits), ± (1.5% rdg + 2 digits) for 200mA range, ± (2.0% rdg + 3 digits) for 15 A range
- overload protection: 500 mA / 600 V, 15 A / 600 V fuse
†DC voltage:
- basic accuracy: ± (0.5% rdg + 2 digits) , ±(0.8% rdg + 2 digits) for 600 V range
- input impedance: 10 MOhm
- maximum input: 600 V
- overload protection: 600 V DC or AC rms
†Diode test: Yes "
†Diode test specifications: test voltage: approx. 3 V (reversed DC voltage)
"
†Frequency:
- basic accuracy: ± (2.0% rdg + 5 digits)
- overload protection: 600 VDC or AC rms
- sensitivity: sine wave 0.5 V rms
†Fuse type: F 0.50 A / 600 VAC / 500 VDC, 5 x 20 mm, breaking capacity 1 kA, F 15 A / 1000 VAC / 1000 VDC, 6 x 32 mm, breaking capacity 10 kA "
†Out of range indication: Yes "
†Temperature measuring Celsius specifications:
- -50 - 150 °C / 150 - 800 °C
- basic accuracy:
- ± (3 °C + 3 digits) for -50 - 150 °C range
- ± (3 % + 3 digits) for 150 - 800 °C range
- overload protection: 500 mA / 600 V fuse
- NiCr-NiSi sensor
- K thermocouple probe: included
†Transistor test: No "
†AC current measurements: 15 A, 2 mA, 20 mA, 200 µA, 200 mA "
†AC voltage measurements: 0-2 V, 20 V, 200 V, 600 V "
†Capacity measurements: 2 µF, 20 nF, 200 µF, 200 nF, 2000 pF "
†DC current measurements: 0.2 mA, 15 A, 2 mA, 20 mA, 200 µA, 200 mA "
†DC voltage measurements: 0-200 mV, 2 V, 20 V, 200 V, 600 V "
†Frequency measurements: 20 kHz "
†Resistance measurements: 0-200 Ohm, 2 kOhm, 2 MOhm, 20 kOhm, 20 MOhm, 200 kOhm, 200 MOhm "
†Resistance specifications:
- basic accuracy: ± ( 1.0% rdg +3 digits) for 200 Ohm range, ± (1.0% rdg + 2 digits) for 2 KOhm to 2 Mohm range, ± (1.5% rdg + 3 digits) for 20 MOhm range, ± (5.0% rdg + 5 digits) for 200 MOhm range
- overload protection: 600 VDC or AC rms
†Safety rating: Cat III / 600 V, Cat IV / 300 V "
†Voltage tester type: AC / DC "
†Automatic power-off function: Yes "
†Pollution degree: 2 "
†Data-hold function: No "†Environmental data: "
†IP rating: IPx0 "
†Usage location: Indoor only "
†Operating temperature °C: 0-40 °C "
†Operating temperature °F: 32-104 °F "
†Storage temperature °C: -20-60 °C "
†Storage temperature °F: -4-140 °F "
†Maximum storage humidity: 90 % "
†Maximum operating humidity: 80 % "†Operational properties: "
†M