Pieejams šodien
Tulkot latviski

LAN Datortīklu kabelis, DAHUA CAT5E UTP kabelis | iekštelpām | 305m | Cena par metru

EB Kods: UTP5E-DAHUA

0,28 
Ar PVN / m
Noliktavā >2000
Ir ElectroBase noliktavā 
-+

 

Conductor
MaterialOxygen free copper (99.97% purity)
Diameter0.45 mm ± 0.01 mm
Insulation
MaterialHDPE
Min. Average Thickness0.18 mm
Diameter0.81mm±0.1mm
Color (4 Pairs)Blue, white/blue; orange, white/orange; green, white/green; brown, white/brown
Rip Cord
MaterialPolyester
Specification500D
Sheath
MaterialPVC
Min. Average Thickness0.5 mm
Diameter4.7 mm ± 0.3 mm
ColorWhite
Electrical
Max. DC Resistance of a Single Conductor12Ω/100 m
Min. Insulation Resistance5000MΩ·km
Max. DC Resistance Unbalance2% (pair intra), 4% (pairs inter)
Dielectric StrengthNo breakdown with 1KV DC for 1 min
Transmission
Characteristic Impedance100 ± 15Ω
Near End Cross Talk≥35.30 dB/100 m@100 MHz
Max. Attenuation24.2 dB/100 m@100 MHz
Return Loss≥20.1 dB/100 m@100 MHz
Mechanical
Tensile StrengthSheath≥13.5 MPa, insulation≥16 MPa
Elongation at BreakSheath≥150%, insulation≥300%
Installation Bending Radius>8 times of outer cable diameter
Conductor Elongation at Break≥10%
Environmental
Shrinkage of Insulation≤5%
Color Migration Resistance of InsulationNo migration
Sheath Tensile Strength and Elongation at Break after Aging≥12.5 MPa, ≥100%
Low Temperature Bending TestNo cracking after the test
Heat Shock TestNo cracking after the test
Operating Temperature–20°C to +60°C (–4°F to 140°F)
Installation Temperature0°C to +50°C (32°F to 122°F)
Storage Temperature and Humidity–10°C to +40°C (14°F to 104°F), <60% (RH)
Security
Vertical Fire Propagation TestComply with IEC 60332-1-2
Packaging
Cable Length305.0 m (1000.66 ft) ± 1.5 m (4.92 ft)
Inner Carton Dimensions364.0 mm × 364.0 mm × 216.0 mm
(14.33" × 14.33" × 8.50") (L × W × H)
Packaging Method305.0 m (1000.66 ft) a carton, 45 pcs/pallet
Net Weight≥7.0 kg (15.43 lb)
Gross Weight≥8.0 kg (17.64 lb)
Compliance
Executive StandardsQ/DXJ 067-2019, EN50575-2014
Certification
CertificationCPR Eca
Note:
Executive standard for the above parameters: Q/DXJ 067-2019"n/s"=Not Specified
"﹡"=Unless otherwise customer stated the test results default to not shown in test report but comply with standard