Specifications
Input (DC)
Recommended max. PV input power 15000 W
Max. PV input voltage 1100 V
Start-up input voltage 160 V
Rated input voltage 580 V
MPP voltage range 140 V – 1000 V
No. of independent MPP inputs 2
No. of PV strings per MPP 1
Max. input current per MPP tracker 13 A
Max. short-circuit current per MPP tracker 16 A
Output (AC)
Rated AC output power 10000 W
Max. AC output apparent power 11000 VA
Rated AC voltage(range) 220/380 V, 230/400 V (340-440 V)
Max. output current 16.7 A
AC grid frequency 50 Hz / 60 H
AC grid frequency range 45 – 55 Hz / 55 – 65 Hz
Harmonic (THD) < 3 % (at rated power)
Adjustable power factor 0.8 leading – 0.8 lagging
AC grid connection type 3 W + N + PE
Efficiency
Max. efficiency 98.6%
European efficiency 98.1%
MPPT efficiency 99.9%
Protection devices
Grid monitoring yes
DC reverse polarity protection yes
AC short-circuit protection yes
Insulation resistance monitoring yes
Surge Protection DC Type II / AC Type II
Ground fault monitoring yes
DC switch yes
String fault monitoring yes
Arc fault circuit interrupter (AFCI) optional
Anti-islanding protection yes
Residual-current monitoring unit yes
General Data
Dimensions(W*H*D) 425*387*178 m
Weight 14 kg
Topology Transformerless
Degree of protection IP66
Night power consumption< 1 W
Operating ambient temperature range-25 °C to +60 °C
Allowable relative humidity range (non-condensing)0% – 100%
Cooling methodNatural convection
Max. operating altitude4000 m
DisplayOLED + LED / WiFi + app
InterfacesRS-485 / USB
Optional interfacesWi-Fi / GPRS / RF / LAN
AC connection typeConnector
CertificationCE, VDE0126, Greece, EN50549, C10/C11, UTE C 15-712, IEC62116, IEC61727, IEC 60068, IEC 61683, CEI0-21, N4105, TOR Erzeuger G98/G99, G100, AS4777, UNE217001, UNE206007, PO12.2


Warranty:
The warranty of the voltage converter (inverter) is valid from the day when we (the seller) is provided with the serial number of the inverter, the purchase invoice, a certified electrician's certificate about the installed:
1) Lightning protection and overvoltage limiter (on the input side)
2) Lightning protection (between solar panels and inverter)
3) DC voltage switch between panels and inverter
4) Dedicate grounding for solar panels separated from grounding of the house


The 10-year (120-month) manufacturer's warranty begins from the day of purchase, but comes into effect only after submission of these documents.