Tulkot latviski
Inverter GROWATT MOD 10KTL3-X, 10kW, 3-phase, 2 MPPT
Inverter GROWATT MOD 10KTL3-X, 10kW, 3-phase, 2 MPPT
EB Kood: EB808692859
Tootja kauba kood: NV820269
Tootja kauba kood:
NV820269
1 150,00 €
Sisaldab käibemaksu / gb
Saadaval tarnija laos 3 tk
⛟ Tarne 1-3 tööpäeva jooksul pärast makse sooritamist.
⛟ Tarne 1-3 tööpäeva jooksul pärast makse sooritamist.
Specifications
Warranty:
The warranty of the voltage converter (inverter) is valid from the day when we (the seller) is provided with the serial number of the inverter, the purchase invoice, a certified electrician's certificate about the installed:
1) Lightning protection and overvoltage limiter (on the input side)
2) Lightning protection (between solar panels and inverter)
3) DC voltage switch between panels and inverter
4) Dedicate grounding for solar panels separated from grounding of the house
The 10-year (120-month) manufacturer's warranty begins from the day of purchase, but comes into effect only after submission of these documents.
Note: Lightning strike is not a valid warranty claim, it is classified as insurance claim.
Input (DC) | |
Recommended max. PV input power | 15000 W |
Max. PV input voltage | 1100 V |
Start-up input voltage | 160 V |
Rated input voltage | 580 V |
MPP voltage range | 140 V – 1000 V |
No. of independent MPP inputs | 2 |
No. of PV strings per MPP | 1 |
Max. input current per MPP tracker | 13 A |
Max. short-circuit current per MPP tracker | 16 A |
Output (AC) | |
Rated AC output power | 10000 W |
Max. AC output apparent power | 11000 VA |
Rated AC voltage(range) | 220/380 V, 230/400 V (340-440 V) |
Max. output current | 16.7 A |
AC grid frequency | 50 Hz / 60 H |
AC grid frequency range | 45 – 55 Hz / 55 – 65 Hz |
Harmonic (THD) | < 3 % (at rated power) |
Adjustable power factor | 0.8 leading – 0.8 lagging |
AC grid connection type | 3 W + N + PE |
Efficiency | |
Max. efficiency | 98.6% |
European efficiency | 98.1% |
MPPT efficiency | 99.9% |
Protection devices | |
Grid monitoring | yes |
DC reverse polarity protection | yes |
AC short-circuit protection | yes |
Insulation resistance monitoring | yes |
Surge Protection | DC Type II / AC Type II |
Ground fault monitoring | yes |
DC switch | yes |
String fault monitoring | yes |
Arc fault circuit interrupter (AFCI) | optional |
Anti-islanding protection | yes |
Residual-current monitoring unit | yes |
General Data | |
Dimensions(W*H*D) | 425*387*178 m |
Weight | 14 kg |
Topology | Transformerless |
Degree of protection | IP66 |
Night power consumption | < 1 W |
Operating ambient temperature range | -25 °C to +60 °C |
Allowable relative humidity range (non-condensing) | 0% – 100% |
Cooling method | Natural convection |
Max. operating altitude | 4000 m |
Display | OLED + LED / WiFi + app |
Interfaces | RS-485 / USB |
Optional interfaces | Wi-Fi / GPRS / RF / LAN |
AC connection type | Connector |
Certification | CE, VDE0126, Greece, EN50549, C10/C11, UTE C 15-712, IEC62116, IEC61727, IEC 60068, IEC 61683, CEI0-21, N4105, TOR Erzeuger G98/G99, G100, AS4777, UNE217001, UNE206007, PO12.2 |
Warranty:
The warranty of the voltage converter (inverter) is valid from the day when we (the seller) is provided with the serial number of the inverter, the purchase invoice, a certified electrician's certificate about the installed:
1) Lightning protection and overvoltage limiter (on the input side)
2) Lightning protection (between solar panels and inverter)
3) DC voltage switch between panels and inverter
4) Dedicate grounding for solar panels separated from grounding of the house
The 10-year (120-month) manufacturer's warranty begins from the day of purchase, but comes into effect only after submission of these documents.
Note: Lightning strike is not a valid warranty claim, it is classified as insurance claim.