Type of meterdigital multimeter
MeasurementAC current
MeasurementAC voltage
MeasurementDC current
MeasurementDC voltage
Measurementinsulation resistance
Measurementresistance
Kind of display usedLCD
Display parameters(6000)
DC voltage measuring range0.1...600mV
DC voltage measuring range6V
DC voltage measuring range60V
DC voltage measuring range600V
DC voltage measuring range1kV
DC voltage measuring accuracy±(0.2% + 2 digit)
AC voltage measuring range0.1...600mV
AC voltage measuring range6V
AC voltage measuring range60V
AC voltage measuring range600V
AC voltage measuring range1kV
AC voltage measuring accuracy±(2% + 3 digit)
DC current measuring range10µA...60mA
DC current measuring range400mA
DC current measuring accuracy±(1% + 2 digit)
AC current measuring range10µA...60mA
AC current measuring range400mA
AC current measuring accuracy±(2% + 2 digit)
True effective value measurementTrue RMS AC
Resistance measuring range100mΩ...600Ω
Resistance measuring range6kΩ
Resistance measuring range60kΩ
Resistance measuring range600kΩ
Resistance measuring range6MΩ
Resistance measuring range50MΩ
Resistance measuring accuracy±(1.2%+2 digit)
Insulation resistance measuring accuracy±(2% + 5digit)
Continuity testacoustic indication
Continuity test<25Ω
IP ratingIP40
Weight with battery550g
Power supplybattery LR6 AA 1,5V x4
Standard equipmentcrocodile clips FLK-AC285
Standard equipmentharda case FLK-C101
Standard equipmenttest leads FLK-TL224 SureGrip
Standard equipmenttest probe FLK-TP165X
Optional equipmentFLK-C25 soft cover
Conform to the normCAT III 1000V
Conform to the normCAT IV 600V
Conform to the normEN 61010
Dimensions (W x H x D)100x203x50mm
Measuring instrument featuresauto and manual ranging
Measuring instrument featuresautomatic discharge of capacitance charge function
Measuring instrument featuresautomatic power-off
Measuring instrument featuresautomatic stop of insulation test when voltage higher than 30V is detected
Measuring instrument featuresHOLD function
Measuring instrument featuresindicates incorrect connection of test leads
Measuring instrument featuresinsulation resistance test
Test voltage500V
Test voltage1kV
Battery/ rechargeable batterybattery LR6 AA 1,5V x4
Insulation resistance measuring ranges0.1...60MΩ
Insulation resistance measuring ranges500MΩ
Illuminationyes