Tulkot latviski

Inverter GROWATT MOD 15KTL3-X, 15kW, 3-phase, 2 MPPT

Code: EB1745254368

Manufacturer's product code: 
NV820276

 1 458,99  
incl. VAT / gb
At supplier's warehouse 3
⛟ Delivery 1-3 working days after payment. 
-+

Specifications
Input (DC)
Recommended max. PV input power 22500 W
Max. PV input voltage 1100 V
Start-up input voltage 160 V
Rated input voltage 580 V
MPP voltage range 140 V – 1000 V
No. of independent MPP inputs 2
No. of PV strings per MPP 1/2
Max. input current per MPP tracker 13/26 A
Max. short-circuit current per MPP tracker 16/32 A
Output (AC)
Rated AC output power 15000 W
Max. AC output apparent power 16500 VA
Rated AC voltage(range 220/380 V, 230/400 V (340-440 V)
Max. output current25 A
AC grid frequency 50 Hz / 60 H
AC grid frequency range 45 – 55 Hz / 55 – 65 Hz
Harmonic (THD) < 3 % (at rated power)
Adjustable power factor 0.8 leading – 0.8 lagging
AC grid connection type 3 W + N + PE
Efficiency
Max. efficiency 98.6%
European efficiency 98.2%
MPPT efficiency 99.9%
Protection devices
Grid monitoring yes
DC reverse polarity protection yes
AC short-circuit protection yes
Insulation resistance monitoring yes
Surge ProtectionDC Type II / AC Type II
Ground fault monitoring yes
DC switch yes
String fault monitoring yes
Arc fault circuit interrupter (AFCI)optional
Anti-islanding protection yes
Residual-current monitoring unityes
General Data
Dimensions (W*H*D) 425*387*178 m
Weight16 kg
Topology Transformerless
Degree of protection IP66
Night power consumption< 1 W
Operating ambient temperature range-25 °C to +60 °C
Allowable relative humidity range (non-condensing)0% – 100%
Cooling methodNatural convection
Max. operating altitude 4000 m
Display OLED + LED / WiFi + app
Interfaces RS-485 / USB
Optional interfaces Wi-Fi / GPRS / RF / LAN
AC connection type Connector
Certification CE, VDE0126, Greece, EN50549, C10/C11, UTE C 15-712, IEC62116, IEC61727, IEC 60068, IEC 61683, CEI0-21, N4105, TOR Erzeuger G98/G99, G100, AS4777, UNE217001, UNE206007, PO12.2




Warranty:

The warranty of the voltage converter (inverter) is valid from the day when we (the seller) is provided with the serial number of the inverter, the purchase invoice, a certified electrician's certificate about the installed:

1) Lightning protection and overvoltage limiter (on the input side)

2) Lightning protection (between solar panels and inverter)

3) DC voltage switch between panels and inverter

4) Dedicate grounding for solar panels separated from grounding of the house




The 10-year (120-month) manufacturer's warranty begins from the day of purchase, but comes into effect only after submission of these documents.

Note: Lightning strike is not a valid warranty claim, it is classified as insurance claim.