Tulkot latviski
DIGITAL MULTIMETER - CAT. II 500 V / CAT. III 300 V - 10 A - AUTO RANGE - 4000 COUNTS
DIGITAL MULTIMETER - CAT. II 500 V / CAT. III 300 V - 10 A - AUTO RANGE - 4000 COUNTS
EB Kods: EB1820439456
Ražotāja preces kods:
DVM855
Ražotāja preces kods:
DVM855
Ražotājs, zīmols: China
Ražotājs, zīmols:
China
37,00 €
Ar PVN / gb
Pieejams piegādātāja noliktavā >10 gab.
⛟ Piegāde 10-15 darba dienas pēc apmaksas.
⛟ Piegāde 10-15 darba dienas pēc apmaksas.
Product basic info: "•†Instruction manual languages: Dutch, English, French, German, Polish, Portuguese, Spanish "•†Primary colours: Grey "•†Additional colours: Red "•†Depth unit: 30 mm "•†Height unit: 138 mm "•†Width unit: 74 mm "•†Weight unit: 120 g "•†Material: ABS "†Physical properties: "•†Cable length: 0.7 m "•†Display height: 21 mm "•†Display width: 47 mm "•†Display type: LCD "•†Backlight: Yes "•†Maximum digits display: 4000 "†Electrical data: "•†AC current:
"•†Automatic polarity indication: Yes "•†Capacity:
- basic accuracy: ± (1.5% rdg + 3 digits), ± (2.5% rdg + 5 digits) for 4 A to 10 A range
- overload protection: 0.5 A / 500 V fuse for µA and mA range, 10 A / 500 V for 10 A range
- basic accuracy: ± (0.8% rdg + 3 digits) , ± (1.2% rdg + 3 digits) for 500 V range
- input impedance: 10 MOhm
- frequency range: 40-500 Hz
- maximum input: 500V DC or AC rms
"•†Automatic polarity indication: Yes "•†Capacity:
- basic accuracy: ± (3.0% rdg + 10 digits), ± (2.5% rdg + 5 digits) for 512 nF to 51.2 µF range, ± (5.0% rdg + 10 digits) for 100 µF range
- overload protection: 500V DC or AC rms
- basic accuracy: ± (1.2% rdg + 2 digits), ± (2.0% rdg + 3 digits) for 4 A to 10 A range
- overload protection: 0.5 A / 500 V fuse for µA and mA range, 10 A / 500 V for 10 A range
- basic accuracy: ± (0.5% rdg + 2 digits) , ± (0.8% rdg + 2 digits) for 500 V range
- input impedance: >, 10 MOhm
- overload protection: 500 V DC or AC rms
- test forward voltage of diode
- test voltage: approx. 1.5 V
- 0,1% bis 99,9%
- Grundgenauigkeit: ± (2,0% rdg + 2 Ziffern)
- Empfindlichkeit: Sinuswelle 0,6 V rms
- Überlastungsschutz: 500V DC oder AC rms
- basic accuracy: ± (0.1% rdg + 5 digits)
- sensitivity: sine wave 0.6 V rms (10 MHz = 1.5 V rms)
- overload protection: 500V DC or AC rms
- basic accuracy: ± ( 1.0% rdg +3 digits), ± (1.0% rdg + 2 digits) for 4 kOhm to 4MOhm range, ± (1.5% rdg + 3 digits) for 40 MOhm range
- overload protection: 500 V DC or AC rms
- basic accuracy: ± (5.0% rdg + 5 digits)
- overload protection: 0.5 A / 500 V fuse