Specification Summary at 20°C (68°F) unless otherwise specified "†resistance: "
†range (resistance): 1Ohm ~ 2MOhm "
†resolution (resistance): 0.3Ohm "
†accuracy (resistance): ±1.0%±1.2Ohm "†capacitance: "
†range (capacitance): 0.5pF ~ 10000µF "
†resolution (capacitance): 0.2pF "
†accuracy (capacitance): ±1.5%±1.0pF "†inductance: "
†range (inductance): 1µH ~ 10H "
†resolution (inductance): 0.4µH "
†accuracy (inductance): ±1.5%±1.6µH "†peak test voltage across O/C: -1.05V ~ +1.05V "†peak test current into short circuit: -3.25mA ~ +3.25mA "†test frequency accuracy: -1.5% ~ +1.5% "†sine purity: -60dB 3rd harmonic "†operating temperature range: 10°C ~ 40°C (50F ~ 104F) "†battery operating voltage: 8.5V ~ 13V "†Weight per product (nett): 0.098kg (3.5oz) "†Dimensions per product: 103 x 70 x 20 mm (4.1" x 2.8" x 0.8")
automatic component identification "†automatic test frequency selection (DC, 1kHz, 15kHz and 200kHz) "†delayed or instant analysis (for hands free operation) "†auto power-off "†probe and test lead compensation "†interchangeable probe sets "†automatic ranging and scaling "†1% basic accuracy for resistors "†1.5% basic accuracy for inductors and capacitors
†range (resistance): 1Ohm ~ 2MOhm "
†resolution (resistance): 0.3Ohm "
†accuracy (resistance): ±1.0%±1.2Ohm "†capacitance: "
†range (capacitance): 0.5pF ~ 10000µF "
†resolution (capacitance): 0.2pF "
†accuracy (capacitance): ±1.5%±1.0pF "†inductance: "
†range (inductance): 1µH ~ 10H "
†resolution (inductance): 0.4µH "
†accuracy (inductance): ±1.5%±1.6µH "†peak test voltage across O/C: -1.05V ~ +1.05V "†peak test current into short circuit: -3.25mA ~ +3.25mA "†test frequency accuracy: -1.5% ~ +1.5% "†sine purity: -60dB 3rd harmonic "†operating temperature range: 10°C ~ 40°C (50F ~ 104F) "†battery operating voltage: 8.5V ~ 13V "†Weight per product (nett): 0.098kg (3.5oz) "†Dimensions per product: 103 x 70 x 20 mm (4.1" x 2.8" x 0.8")
automatic component identification "†automatic test frequency selection (DC, 1kHz, 15kHz and 200kHz) "†delayed or instant analysis (for hands free operation) "†auto power-off "†probe and test lead compensation "†interchangeable probe sets "†automatic ranging and scaling "†1% basic accuracy for resistors "†1.5% basic accuracy for inductors and capacitors